Elecraft KX3 Programmers Reference Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Acessórios de comunicações Elecraft KX3 Programmers Reference. Elecraft KX3 Programmers Reference User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 26
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
1
ELECRAFT K3 AND KX3
PROGRAMMER'S REFERENCE
Rev. E11, Oct. 24, 2013
(For change history, see Appendix A)
Vista de página 0
1 2 3 4 5 6 ... 25 26

Resumo do Conteúdo

Página 1 - PROGRAMMER'S REFERENCE

1 ELECRAFT K3 AND KX3 PROGRAMMER'S REFERENCE Rev. E11, Oct. 24, 2013 (For change history, see Appendix A)

Página 2 - Command Set Overview

10 DT (DATA Sub-Mode; GET/SET) SET/RSP format: DTn; where n is the data sub-mode last used with VFO A, whether or not DATA mode is in effect: 0 (D

Página 3 - Response Time

11 FW $ (Filter Bandwidth and Number; GET/SET) NOTE: FW is a legacy K2 command with side-effects based on the K3x and K2x meta command set

Página 4 - Meta-commands: AI, K2 and K3

12 IC (Misc. Icons and Status; GET only) RSP format: ICabcde; where abcde are 8-bit ASCII characters (Byte in Table 4 below) used as collections o

Página 5 - Command Examples

13 ID (Transceiver Identifier; GET only) RSP format: IDnnn; where nnn is 017. This command is provided only for compatibility with existing softwa

Página 6 - Simple Application Program

14 K3 * (Command Mode; GET/SET) SET/RSP format: K3n; where n is 0-1. If n is 1, enables K3-specific command extensions to legacy “2-letter” comman

Página 7 - Command Reference

15 sets both main and sub mode to n. (2) DATA and DATA-REV select the data sub-mode that was last in effect on the present band. (To read/set data s

Página 8

16 MN (Menu Selection; GET/SET; K3 and KX3 variants) SET/RSP format: MNnnn; where nnn is shown in Table 5 (K3) or Table 6

Página 9

17 Table 6 KX3 MN values. These are the same as the K3’s only if the two are functionally identical. nnn is permanently assoc

Página 10

18 MP (8-bit Direct Menu Parameter Access; GET/SET) SET/RSP format: MPnnn; where the useful range of nnn is determined by the present menu entry (

Página 11

19 SET/RSP format: NBn; or NB$n; where n is 0 (OFF) or 1 (ON). Notes: NB0 always turns the noise blanker off, overriding any non-zero NL settin

Página 12 - BAND SEL

2 Command Set Overview All K3/KX3 remote control commands are listed in Table 1. The KX3 accepts all K3 commands, though some have no functional eff

Página 13

20 PS (Transceiver Power Status; GET/SET) SET/RSP format: PSn; where n = 1 indicates transceiver on. Note: PS0 turns the transceiver off, but this

Página 14

21 SB * (Sub Receiver or Dual Watch On/Off) SET/RSP format: SBn; where n is 0 (sub receiver or dual watch off) or 1 (on). K3: Sub RX; KX3: Dual

Página 15

22 SWT/SWH (Switch Emulation; SET only; K3 and KX3 variants) SET format: SWTnn; (TAP functions) or SWHnn; (HOLD functions). nn is determined f

Página 16

23 TB (Received Text Read/Transmit Text Count; GET only) RSP format: TBtrrs; where t is the count of buffered CW/data characters remaining to

Página 17

24 XF $ (XFIL Number; GET only) RSP format: XFn; where n is the present XFIL selection (1-5) for the target receiver. In the K3, the XFIL selectio

Página 18

25 Appendix A: Change History [Applicable MCU revisions shown in brackets] Note: Prior to revision D1 this document applied only to the K3. For

Página 19

26 E5, 1-3-2013 [K3, rev 4.51; KX3, rev 1.35] ! [KX3] Added bit to “IC” command to show state of OFS/VFOB LEDs. See byte (e) bit (1). E6, 2-26-

Página 20

3 Command Format Note: In the remainder of this document, K3 references apply to the KX3 as well unless otherwise noted. Commands sent from the comp

Página 21

4 Meta-commands: AI, K2 and K3 Meta-commands change the behavior of other commands to provide automatic responses or compatibility with older applic

Página 22

5 Command Examples Macros Macros – strings containing one or more control commands – can be used to automate K3/KX3 front panel switch sequences. Ta

Página 23

6 Creating and Using Macros K3 Utility and KX3 Utility can be used to create and test macros. The first eight of these can be sent to the transceive

Página 24 - XT (XIT Control; GET/SET)

7 Command Reference Note: Commands marked with a dollar sign ($) apply to VFO B (and the sub receiver, in the case of the K3). Commands marked with

Página 25

8 BR (Serial I/O Baud Rate; SET only) SET format: BRn; where n is 0 (4800 b), 1 (9600 b), 2 (19200 b), or 3 (38400 b). Note: The K3 firmware do

Página 26

9 DS (VFO A and Basic Icon Read; GET only) GET format: DS; (no data). Returns everything needed to reproduce the contents of the VFO A display, as

Comentários a estes Manuais

Sem comentários