The W2 serial port is configured for 9600 baud, 8 databits, 1 stopbit, no handshake.
Purpose Purpose
String Length 3 chars. display of Forward Power LED's.
Response String Length 3 chars.
Notes Response
Notes
Purpose Purpose
String Length
Response String Length 3 chars.
Notes Response
Notes
Purpose Purpose
String Length 3 chars. String Length 3 chars.
Response Response
Notes Notes
Purpose Purpose
String Length String Length 3 chars.
Response Response
Notes Notes
Purpose Purpose
String Length 9 chars. String Length 9 chars.
Response Response
Notes
Notes
Purpose Purpose
String Length 13 chars. String Length 5 chars
Response Response
Notes Notes
Purpose Purpose
String Length 3 char. String Length 6 chars.
Response Response
Notes Notes
A
or
a
Toggle locking SWR Alarm On/Off.
"0" is non-locking, "1" will lock.
Command
Toggles between Average or PEP
EEPROM: No
EEPROM: Yes
Elecraft W2 Serial Interface Commands
Revision D, April 12, 2010. Applies to firmware rev 1.00 or higher.
Copyright © 2009 - 2010, Elecraft, Inc.; All Rights Reserved
The W2 responds to commands for data supplied by the external system. Nothing is sent until a command is received by the
W2. These requests are in the form of a single letter as shown below. The user sends a single character and receives one data
string in response. The semicolon (;) is an end-of-string identifier, and will be at the end of every return string. The strings
vary in length. Use the table below to determine the output from your command input.
Returns only [C/c] if not in Alarm.
"1" = Sensor1, "2" = Sensor2.
[A/a][0/1];
Command
Toggles between Average or PEP
Command
B
or
b
[P/p][0/1];
EEPROM:
EEPROM:
EEPROM: Yes
EEPROM: Yes
C
or
c
Reset from SWR Alarm
O
or
o
Toggles between two Sensors.
[C/c]!;
[O/o][1/2];
EEPROM: No
[N/n][A/P];
Command
D
or
d
P
or
p
Toggles Peak-Hold LED On/Off.
Command
F
or
f
Request Forward Power in Watts.
Request Reverse Power in Watts.
[R/r]nnnnnDn;
(Watt value) -D- (number of
Same as "F" (left)
EEPROM: No
L
or
l
Toggles W2 LED's On/Off
V
or
v
Request Firmware version.
[L/l][0/1];
Vn.nn;
"0" is LED's Off, "1" is LED's On.
n.nn is the version 0.01 to 9.99
EEPROM: Yes
EEPROM: No
E l e c r a f t w w w . e l e c r a f t . c o m 8 3 1 - 7 6 3 - 4 2 1 1
R
or
r
decimal places).
M
or
m
[M/m][A/P];
"A" = Average, "P" = PEP.
N
or
n
"A" = Average, "P" = PEP.
value of Power serial data.
EEPROM: No
I
or
i
Request W2 config information.
[F/f]nnnnnDn;
[I/i][Info String];
See page 3 for String details.
EEPROM: Yes
EEPROM: No
EEPROM: No
Command
Command
S
or
s
Request the SWR value.
[S/s]nnnn;
nnn has implied dp "nn.nn".
"0" = Off, "1" = On.
Vista de página 0
1 2 3

Resumo do Conteúdo

Página 1

Page 1The W2 serial port is configured for 9600 baud, 8 databits, 1 stopbit, no handshake.Purpose PurposeString Length 3 chars. display of Forward Pow

Página 2

Page 2The W2 serial port is configured for 9600 baud, 8 databits, 1 stopbit, no handshake.Purpose PurposeString Length String Length 3 chars.Response

Página 3 - W2 Sensor Calibration

Page 3Byte Property1 "I" or "i" (echoes back what you sent).2 Active Sensor (1 or 2) matching the "S1/S2" LED lit.3 Rang

Comentários a estes Manuais